Sutnan Capacitor Information

Jul 15, 2008 at 17:15 o\clock

Tantalum Capacitor Overview

by: hkcapacitor   Keywords: Tantalum, Capacitor

In tantalum capacitor manufacturing, there is a steam pyrolysis process where tantalum pellets are decomposed by steam. Humidity control in this process is important to maintain product quality and improve yield. Stable humidity measurement at high temperatures of 200 to 400 °C is required. The ZR402G/HS Direct In Situ Zirconia High Temperature Humidity Analyzer is easy to maintain as it requires no sampling system and utilizes a long life sensor with fast response.

Expected Benefits
Maintains the quality of the tantalum capacitor manufacturing process
Ensures stable, continuous humidity measurement
Reduces operating costs

Process Overview
A tantalum pellet with an electrode plate applied is immersed in a manganese nitrate solution. This dipping process allows the manganese nitrate to penetrate the porous part of the pellet. After dipping, the pellet is forwarded to the pyrolysis process where the manganese nitrate is decomposed under high temperature and humidity conditions to form a manganese dioxide coating by the reaction Mn(NO3)2 -> MnO2 + 2NO2. These steps are repeated until the coating is sufficient. To improve the coating uniformity and yield, the humidity is controlled.


Comment this entry


Captcha

Attention: guestbook entries on this weblog have to be approved by the weblog\s owner.